Vaillant Boiler Error Codes — Complete Guide

Every Vaillant fault code explained. Quick fixes you can try yourself and when to call a Gas Safe engineer.

Gas Safe Registered #587248 5-Star Google Reviews Same Day Available All London Areas Fixed Price Quotes

📊 Vaillant Error Codes — Full Reference Table

CodeMeaningDIY Fix?
F.28Ignition failure — no gas or ignition faultCheck gas supply only
F.29Flame loss during operationReset — call if persists
F.75Pressure sensor / pump faultCheck pressure, call engineer
F.22Low water pressureRepressurise system
F.24Temperature rise too fast — possible pump faultCall engineer
F.83Flue temperature sensor faultCall engineer
F.61Gas valve regulation faultCall engineer urgently
S.04Boiler in anti-cycling mode (normal)No action needed
S.06Boiler in freeze protection modeCheck heating, no action

🔥 F.28 and F.29 — Ignition Faults (Most Common)

F.28 means the boiler failed to ignite. F.29 means the flame went out during operation. These are the two most common Vaillant fault codes.

What to try first:

  1. Check other gas appliances — does your hob work? If not, call National Gas Emergency: 0800 111 999
  2. Press the Reset button (🔄 symbol) on the boiler display
  3. Wait 30 seconds and see if it fires up
If F.28 or F.29 keeps returning after 2-3 resets: Stop resetting. Repeated reset attempts can damage the gas valve. Call FE Maintenance on 020 8445 1303 for a same-day diagnosis.

Common causes requiring an engineer:

  • Faulty ignition electrode or lead
  • Blocked or dirty burner
  • Faulty gas valve
  • Printed circuit board (PCB) fault

💧 F.22 and F.75 — Pressure Problems

F.22 is a simple low pressure fault — your boiler pressure has dropped below the minimum. F.75 is more serious — it suggests the pressure sensor or pump may be faulty.

Fixing F.22 — How to repressurise your Vaillant boiler:

  1. Switch the boiler off and let it cool
  2. Find the filling loop (flexible hose under the boiler)
  3. Slowly open both valves until the pressure gauge shows 1.0-1.5 bar
  4. Close both valves tightly
  5. Press Reset on the boiler
If your Vaillant keeps losing pressure: You likely have a small leak somewhere in the system — radiator valve, pipe joint, or expansion vessel fault. FE Maintenance can diagnose and fix the source.